Acopia Networks 810-0044-00 Manual de instalación Pagina 245

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 492
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 244
Adding a Managed Volume
Selecting a VPU (optional)
CLI Storage-Management Guide 9-51
VPU 2
-----
Physical Processor: 3.2
State: Normal; maximum instances
Share credits: 7 shares used (249 credits remain of total 256)
Direct share credits: 5 direct shares used (4091 credits remain of total 4096)
Volume credits: 6 volumes used (58 credits remain of total 64)
File credits: 132M files reserved (252M credits remain of total 384M)
Namespace Domain Volume State
--------- ------ ------ -----
medarcv 1 /rcrds Enabled
medarcv 1 /lab_equipment Enabled
medarcv 1 /test_results Enabled
insur 2 /claims Enabled
2 Namespaces 4 Volumes
bstnA6k(gbl-ns-vol[medarcv~/rcrds])# ...
Showing One VPU
To focus on one VPU, use the VPU number with the show vpu command. For
example, the following command shows VPU 1:
bstnA6k(gbl-ns-vol[medarcv~/rcrds])# show vpu 1
Switch: bstnA6k
----------------------------------------------------------------------
VPU 1
-----
Physical Processor: 3.1
State: Normal; maximum instances
Share credits: 4 shares used (252 credits remain of total 256)
Direct share credits: 3 direct shares used (4093 credits remain of total 4096)
Volume credits: 2 volumes used (62 credits remain of total 64)